Technical Requirements Table

Designlights™ Consortium Qualified Products List- Non-Residential Applications —
Submit any or all of the following product Information and Testing Results to Designlights for qualification
*please make note that it is ONE per submission*
PDF Download

Application

Minimum Light Output

Maximum Light Output

Zonal Lumen Density

Minimum Luminaire Efficacy

Allowable CCTs
(ANSI C78.377-2008)

Minimum CRI

Minimum L70 Lifetime

Outdoor Pole/Arm-Mounted Area and Roadway Luminaires

1,000 L

N/A

100% 0–90º, <10% 80–90º plus meet IES Type I, II, III, IV, or V

50 L/w

N/A

50

50,000 hrs

Outdoor Pole/Arm-Mounted Decorative Luminaires

1,000 L

N/A

95% 0–90º

40 L/w

N/A

50

50,000 hrs

Outdoor Wall-Mounted Area Luminaires

300 L

N/A

100% 0–90º,
<10% 80–90º

40 L/w

N/A

50

50,000 hrs

Parking Garage Luminaires

2,000 L

N/A

>20% 60–70º,

>15% 70–80º

56 L/w

N/A

50

50,000 hrs

Track or Mono-point Directional Lighting Fixtures

250 L

N/A

>85% 0–90º

30 L/w

2700K, 3000K, 3500K, 4000K, 5000K

50

50,000 hrs

Refrigerated Case Lighting

Center-mounted*:

>100 lm/ft

End-mounted**:

>50 lm/ft

 

Center-mounted*:

<300 lm/ft

End-mounted**:

<150 lm/ft

0º-80º: >95%

35 lm/W 2700K, 3000K, 3500K, 4000K, 4500K and 5000K 70 50,000 hrs AND 5-year warranty
Display Case Lighting

End-mounted**:

>50 lm/ft

End-mounted**:

<150 lm/ft

0º-80º: >95% 35 lm/W 2700K, 3000K, 3500K, 4000K, 4500K and 5000K 75 35,000 hrs AND 3-year warranty

Linear Panels

(2x2 Troffer ONLY)

>3000 lm N/A 30º-60º: >=50% 55 lm/W 2700K, 3000K, 3500K,
4000K, 4500K, 5000K
80 35,000 hrs AND 3-year warranty
Highbay, Outdoor Retrofit Kits- COMMING SOON

Source for Outdoor Specs- DOE ENERGY STAR® Eligibility Criteria – Version 1.1 December 19, 2008

(www.drintl.com/temp/ENERGYSTAR_SSLCriteria_V1_1.pdf)

*Bilateral, symmetric light distribution on two hemispheres
**One-sided, single hemisphere light distribution

 

Disclaimer: DesignLights™ Consortium Qualified Products List holds the right to make revisions or changes to current specifications at any given period.  Manufacturers will be given advance notice when these changes occur.

Please proceed to the next page

DOE ENERGY STAR V1.1 Non-Residential Applications – Products must be ENERGY STAR qualified

Application

Minimum Light Output

Maximum Light Output

Zonal Lumen Density

Minimum Luminaire Efficacy

Allowable CCTs
(ANSI C78.377-2008)

Minimum CRI

Minimum L70 Lifetime

Recessed, surface and pendant-mounted downlights

<4.5" 345 L, >4.5" 575 L

 

75% 0º–60º

35 L/w

2700 K, 3000 K, 3500 K, 4000K, 5000K

75

35,000 hrs

Under cabinet shelf-mounted task Lighting

125 L/ft

 

60% 0º–60º,
25% 60º–90º

29 L/w

2700K, 3000K, 3500K, 4000K, 5000K

75

35,000 hrs

Portable desk task lights

200 L

 

85% 0º–60º

29 L/w

2700K, 3000K, 3500K, 4000K, 4500K and 5000K

75

35,000 hrs

Wall wash luminaires

575 L

 

50% 20º–40º

40 L/w

2700K, 3000K, 3500K, 4000K, 4500K and 5000K

75

35,000 hrs

Bollards

N/A

 

<15% 90º–110º, 0% >110º

35 L/w

NA

75

35,000 hrs